K5 series open loop current sensor 500A Hall current sensor 500A 800A 1000A 1500A 2000A

K5 series dismountable hall effect current sensor is an open loop device based on the measuring principle of the hall effect, with a galvanic isolation between primary and secondary circuit. It provides accurate electronic measurement of DC, AC or pulsed currents. Electrical data (Ta=25ºC±5ºC,RL=2KΩ,C

Featured Products

K5 series dismountable hall effect current sensor is an open loop device based on the measuring principle of the hall effect, with a galvanic isolation between primary and secondary circuit. It provides accurate electronic measurement of DC, AC or pulsed currents.
 

Electrical data (Ta=25ºC±5ºC,RL=2KΩ,CL=10000PF)
TypeK5-500AK5-800AK5-1000AK5-1500AK5-2000AUnit
Rated current(Ipn)±500±800±1000±1500±2000A
Measure range(Ip)0-±10000-±16000-±20000-±30000-±3000A
Rated output@Ip=±Ipn               ±4±1%V
Supply voltage±12,±15V
Power Consumption<25mA
Offset voltage@Ip=0                     ±20mV
Magnetic offset@Ip=±Ipn-0                ±20mV
Offset drift@ -40~+85ºC               ≤±1mV/ºC
Output drift@ -40~+85ºC               ≤±1mV/ºC
Linearity@Ip=0-±Ipn                 ≤1%FS
Response time@50A/μS, 10%-90%         ≤7μs
Galvanic isolation@ 50HZ,AC,1min              6KV
Isolation resistance@ DC 500V                 1000
 
Applications
·Variable speed drives
·Welding machine
·Battery supplied applications
·Uninterruptible Power Supplies (UPS)
· Electrochemical
 
Mechanical dimension(for reference only)
K5 Series Open Loop Current Sensor 500A Hall Current Sensor 500A 800A 1000A 1500A 2000A
Remarks:
1. All dimensions are in mm.
2. General tolerance ±1mm.
3. Elucidation:  1:+15V  2:-15V  3:V0UT  4:0V
 
Directions for use
1. When the current will be measured goes through a sensor, the voltage will be measured at the output end.(Note: The false wiring may result in the damage of the sensor)
2. Custom design in the different rated input current and the output voltage are available.

 
Standards
·UL94-V0.
·EN60947-1:2004
·IEC60950-1:2001
·EN50178:1998
·SJ 20790-2000
 
General date
 ValueUnit
Operating temperature (TA)-40 to +85ºC
Storage temperature(TS)-40 to +125ºC
Mass(approx) (M)400g
 
Characteristics chart

Effects of impulse noise:K5 Series Open Loop Current Sensor 500A Hall Current Sensor 500A 800A 1000A 1500A 2000A

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours