Power Monitoring Control And Medical Equipment Safety Bar DC current Voltage Signal IsolatorZero/Gain and Full Scale Adjustable Magneto-electric Isolation TransmitterFeatures:Precision grade: 0.1, 0.2, 0.5, nonlinearity grade (in full measuring range) <0.2%.Zero, Gain, Full scale calibration are available through external mul

Featured Products

Power Monitoring Control And Medical Equipment Safety Bar DC current Voltage Signal Isolator

Zero/Gain and Full Scale Adjustable Magneto-electric Isolation Transmitter
Features:
Precision grade: 0.1, 0.2, 0.5, nonlinearity grade (in full measuring range) <0.2%.
Zero, Gain, Full scale calibration are available through external multi-turn potentiometer.
Isolation power among auxiliary power, analog input, output: 3000VDC
Auxiliary power: 5V,12V,15V,24VDC, etc.
Isolation, amplification and conversion among 0-75mV/ 0-5V/ 0-10V/ 0-1mA/ 0-20mA/ 4-20mA analog signal.
Industrial temperature range: -20 ~ +70 ºC
Electro-magnetic anti-interference circuits /shielding measures are required in the field with special EMC.
Low cost, compact SIP 12Pin, UL94V-0 standard flame retardant package.

Applications:
DC current/voltage signal isolation, conversion and amplification.
Long-distance isolated transmission of industrial site signals.
Analog signal GND wire anti-interference and data isolated acquisition.
Meters, instruments and sensors signal acquisition and transmission.
Isolated data acquisition of analog signals from PLC, DCS.
VFD/transducer signal long-distance transmission without distortion.
Power monitoring control, medical equipments isolated safety bar.
4-20mA sensor analog signal 1x2, 2x2, 1x4 isolated amplification and transmission.
 
categoryIsolation Amplifier >> Isolation Transmitter with Distribution Power  
input0-75mV/0-2.5V/0-5V/0-10V/0-±100mV/0-±5V/0-±10V/0-10mA/0-20mA/4-20mA/0-±10mA/0-±20mAoutput 0-75mV/0-2.5V/0-5V/0-10V/0-±100mV/0-±5V/0-±10V/0-10mA/0-20mA/4-20mA/0-±10mA/0-±20mA
Isolation Method: electromagnetic isolationIsolation Voltage: 3000VDC
packageSIP 12pin  
Remark:Zero/Gain Adjustable Magneto-electric Isolation Transmitter/Amplifier IC  
Power Monitoring Control and Medical Equipment Safety Bar DC Current Voltage Signal Isolator
Power Monitoring Control and Medical Equipment Safety Bar DC Current Voltage Signal Isolator
Power Monitoring Control and Medical Equipment Safety Bar DC Current Voltage Signal Isolator
Power Monitoring Control and Medical Equipment Safety Bar DC Current Voltage Signal Isolator
 

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours