Acrel Split Core Hall Current Sensor with DC 0-1000A Input Ahkc-Ekba

Product DescriptionAHKC-EKBA Split Core Open-loop Hall Effect Current SensorGeneralHall current sensors are mainly used to isolate and convert AC, DC, pulse and other complex signals. After signals are converted according to the Hall Effect Theory, they can be directly acquired by AD, DSP, PLC, secondary instruments and oth

Featured Products

Product Description

AHKC-EKBA Split Core Open-loop Hall Effect Current Sensor

General

Hall current sensors are mainly used to isolate and convert AC, DC, pulse and other complex signals. After signals are converted according to the Hall Effect Theory, they can be directly acquired by AD, DSP, PLC, secondary instruments and other devices. Hall current sensors are widely applicable for acquisition and feedback control of current signals in the current monitoring, battery application, inverter, solar power management, direct current cabinet, DC motor drive, electroplating, welding, frequency converter, UPS servo control systems. They feature the quick response, wide range of measurement, high precision, strong overload capacity, good linearity and excellent anti-interference performance.

Features
1.Measure AC, DC, pulse and other complex current
2.Small package size
3.Low power consumption
4. Extended measuring range


Application
1.AC variable speed drives
2. Battery supplied applications
3. Uninterruptible Power Supplies
4.Power supplies for welding application

 
Technical Parameters
Technical parametersData
Split/closed  open-loopHall (true RMS)
OutputNominal valueVoltage: ±5V/±4VCurrent: 4-20mA
Zero offset voltage (current)Voltage: ±20mVCurrent:±0.05mA
Offset voltage (current) driftVoltage: ≤±1.0mV/ºCCurrent:±0.04mA/ºC
Linearity≤0.2%FS
Power voltageDC±15VDC 24V
Bandwidth 0-20kHz 
Response time   ≤5us≤1ms
Dielectric strengthPermissible 2500VAC between input/ output and power supply at the power frequency
Accuracy class1.0
Ambient conditionsTemperatureOperating temperature:-25ºC-+70ºC;
storage temperature: -40ºC-+85ºC
Humidity≤95%RH, no dew, no aggressive gas
Altitude≤3500m



Quotation
Acrel Split Core Hall Current Sensor with DC 0-1000A Input Ahkc-Ekba


Acrel Split Core Hall Current Sensor with DC 0-1000A Input Ahkc-Ekba
Acrel Split Core Hall Current Sensor with DC 0-1000A Input Ahkc-Ekba

Acrel Split Core Hall Current Sensor with DC 0-1000A Input Ahkc-Ekba

Contact us