Product DescriptionAHKC-EKBA Split Core Open-loop Hall Effect Current Sensor
Hall current sensors are mainly used to isolate and convert AC, DC, pulse and other complex signals. After signals are converted according to the Hall Effect Theory, they can be directly acquired by AD, DSP, PLC, secondary instruments and other devices. Hall current sensors are widely applicable for acquisition and feedback control of current signals in the current monitoring, battery application, inverter, solar power management, direct current cabinet, DC motor drive, electroplating, welding, frequency converter, UPS servo control systems. They feature the quick response, wide range of measurement, high precision, strong overload capacity, good linearity and excellent anti-interference performance.
Features
Quotation
AHKC-EKBA Split Core Open-loop Hall Effect Current Sensor
General
Hall current sensors are mainly used to isolate and convert AC, DC, pulse and other complex signals. After signals are converted according to the Hall Effect Theory, they can be directly acquired by AD, DSP, PLC, secondary instruments and other devices. Hall current sensors are widely applicable for acquisition and feedback control of current signals in the current monitoring, battery application, inverter, solar power management, direct current cabinet, DC motor drive, electroplating, welding, frequency converter, UPS servo control systems. They feature the quick response, wide range of measurement, high precision, strong overload capacity, good linearity and excellent anti-interference performance.Features
1.Measure AC, DC, pulse and other complex current
2.Small package size
3.Low power consumption
4. Extended measuring range
Application
1.AC variable speed drives
2. Battery supplied applications
3. Uninterruptible Power Supplies
4.Power supplies for welding application
Technical Parameters2.Small package size
3.Low power consumption
4. Extended measuring range
Application
1.AC variable speed drives
2. Battery supplied applications
3. Uninterruptible Power Supplies
4.Power supplies for welding application
Technical parameters | Data | |||
Split/closed open-loop | Hall (true RMS) | |||
Output | Nominal value | Voltage: ±5V/±4V | Current: 4-20mA | |
Zero offset voltage (current) | Voltage: ±20mV | Current:±0.05mA | ||
Offset voltage (current) drift | Voltage: ≤±1.0mV/ºC | Current:±0.04mA/ºC | ||
Linearity | ≤0.2%FS | |||
Power voltage | DC±15V | DC 24V | ||
Bandwidth | 0-20kHz | |||
Response time | ≤5us | ≤1ms | ||
Dielectric strength | Permissible 2500VAC between input/ output and power supply at the power frequency | |||
Accuracy class | 1.0 | |||
Ambient conditions | Temperature | Operating temperature:-25ºC-+70ºC; storage temperature: -40ºC-+85ºC | ||
Humidity | ≤95%RH, no dew, no aggressive gas | |||
Altitude | ≤3500m |
Quotation