2 loop (512 points) addressable fire alarm control panel (closed loop wiring, linkage type)

Fire Alarm Controller (linkage type) fire fightingThis linkage type fire alarm controller mainly to be used in middle and big size fire fighting project. It is the fire fighting master. Features:★ Capacity of the panel: 2 loops, 512 addressable point (loop device address, excluding panel device address)

Featured Products

Fire Alarm Controller (linkage type) fire fighting

This linkage type fire alarm controller mainly to be used in middle and big size fire fighting project. It is the fire fighting master. 
2 Loop (512 Points) Addressable Fire Alarm Control Panel (Closed loop wiring, Linkage type)
2 Loop (512 Points) Addressable Fire Alarm Control Panel (Closed loop wiring, Linkage type)
2 Loop (512 Points) Addressable Fire Alarm Control Panel (Closed loop wiring, Linkage type)
2 Loop (512 Points) Addressable Fire Alarm Control Panel (Closed loop wiring, Linkage type)
2 Loop (512 Points) Addressable Fire Alarm Control Panel (Closed loop wiring, Linkage type)
Features:
 Capacity of the panel: 2 loops, 512 addressable point (loop device address, excluding panel device address), 1 loop special audio and video output, 8 linkage panel.
 Setting and operation of detection and alarm zone supported, detection zone includes input devices such as detectors and manual call points, alarm zone consists of output devices including sounders.
 320*240 single-colors LCD to display the status of panel network, each press button to be operate conveniently and quickly.
 Display by Chinese /English, to convert language by language script technology, to realize different language display of agility and convenience.
 Network with E/EN Series CIE by CAN bus mode.
 To realize Ethernet communication with other equipment by LD198EL-E Ethernet connector card . Network communication adopts multipriority circular network technology, reliable and real time . Two physical connection modes: optical fiber and cable among different node equipments. To realize circular network by LD198EL-E network card (RS485 communication) and /or LD198EL-E fiber connector card (fiber communication).
 User implements programming work by special software, user is able to choose different communication mode to realize upload and download of configuration database by Ethernet, parallel, SD card , U-key.
 Black box function is able to preserve event records of 9 types: 1024 fire alarm, 1024 fault, 1024 start, 256 supervision, 256 disablements, 256 delays, 226 pre-alarm, 256 gas-extinguishing, and 256 CIE operations.
 User's access level control. There are three user access levels.
 One pair of passive connector for common alarm. One for common fault.
 Supervisory alarm function.
★Short circuit protection in the loop and power supply.
 To support circular wiring method of detection bus.
To support circular wiring method of detection bus.
LD198EL-E control and indicating equipment employs circular network communication technology with multi-priority, enabling peer-to-peer communication among node equipments. compared with other network technology, circular network is more reliable and practical. capable of solving data conflict problem effectively. multi-priority processing technology helps to guarantee high response for events with high priority, enabling alarm message from any node to be transmitted to central CIE within 3s.
LD198EL-E CIE carries out automatic inspection on hardware, equipment and network. suppose any part of local CIE appears to fault, fault message will be sent out until it is eliminated. suppose interruption or short-circuit occurs, regroup the disconnected parts immediately and configure them as a sub net.

Main technology specifications:
ContentTechnical Data
Power supplyAC 220V(187V-242V)50Hz
Output voltage to the loopDC14V~24V
Output to the panelDC24V/2A
Number of loop2
Max. Number of addressable codes512(addressable of loop device , excluding panel)
Max. Output current to the loop200mA
Max. Protection current for short-circuit400mA
Unload power≤ 30W
ZoneDetection zone999
Alarm zone999
Operating temperature0ºC~50ºC
Relative humidity≤ 95%RH(40±2ºC)
Mounting methodWall-mounted
Battery2*12V/14Ah
Max. External dimension456(W)mm×180(D)MM×620(H)mm
Weight18.0kg ± 0.1kg
 




 

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours