5-600A 50-400Hz Split Core Current Transformer for Current Measurement

0.5-600A 0.333V Transformer Split with ETLProduct Description0.333-3.53V  split core current transformer with core currentTIANJIN GREWIN TECHNOLOGY CO.,LTD.GWSCCT series split core current transformer  Part numberRated input(A)Second output(V)Accuracy classLimit primary current(A)Accuracy classFrequency(Hz)Ou

Featured Products

0.5-600A 0.333V Transformer Split with ETL
0.333V Split CT Current Transformer for Electrical Motor and HVAC
Product Description
0.333-3.53V  split core current transformer with core current
TIANJIN GREWIN TECHNOLOGY CO.,LTD.
GWSCCT series split core current transformer  
Part numberRated input(A)Second output(V)Accuracy classLimit primary current(A)Accuracy classFrequency(Hz)OutlineDimensions ID-L-W-H(mm)Unit weightTurn ratioOutput cable
GWSCCT0055  10  150.3331.0 3.0--50-4005.0-25.0-22.5-34.530g3000:1wire(1m)
GWSCCT0105,10,20,50,750.3331.0 3.01205P 10P50-40010-29.4-26.4-41.750g3000:1wire(1m)
GWSCCT01675,100,1500.3330.5 1.03005P 10P50-40016-36.9-39.2-52.9100g3000:1wire(1m)
GWSCCT024100,150,200,2500.3330.5 1.05405P 10P50-40024-51.2-47-70.2250g3000:1wire(1m)
GWSCCT035200,300,400,6000.3330.5 1.06005P 10P50-40035-65.8-51.2-83.5400g3000:1wire(1m)
5-600A 0.333V Split Core Current Transformer

GWSCCT Series Split Core Current Sensor (Specifications)

Rated Primary current

5-600A

Rated Secondary current

0.333V-3.53V

Rated load

1, 2.5, 5.0, 10, 30VA

Accuracy

0.5, 1.0, 3.0 Class

Rated Short-time thermal current (Ith)

20In

Rated Dynamic current (Idyn)

2.5Ith

Case Material

 UL flame retardant rating 94-V0

Highest Voltage for Equipment Um (rms)

720 Vac

Rated Power-Frequency Withstand Voltage(rms)

3,000 Vac 

Frequency Range:

50/60Hz

Operating Temperature

 -15ºC to 50ºC

Standard

IEC 60044-1

Accessories

Supplied with feet for base mounting if required

Certification

RoHS compliant CE&ETL approved

GWSCCT Series Split Core Current Sensor  (Features)

Low cost

5 standard sizes

Split core design, safer, easier installation, and portable

GWSCCT Series Split Core Current Sensor  (Applications)

Measures AC current flow to electric motors, lighting, air condition equipment, etc. 

Compatible with HVACtemperature control, power management, building 

The GREWIN SCCT series of split core ct style current sensors are designed for fast and easy installation.The split core design permits non-contactcurrent measurements through magnetic field induction without disconnecting cables or busbar circuits for CT installation. This method permits a safer, easier and portable current measurement.
0.333-3.53V rated secondary output split core current transformer :
 5-600A 0.333V Split Core Current Transformer

Model No 1 :GWSCCT 010
Ratio : 3000:1
Rated input: 5A 10A 20A 50A 75A
Accuracy class: 1.0s  3.0s
Rated primary current :120A
Protection: 5 times protection ,10 times protection like 25A 50A 100A 200A 250A 385A 500A 750A
 
Model No.2 :GWSCCT016
Ratio :3000:1
Rated input: 75A 100A 150A
Accuracy class: 0.5 1.0S
Rated accuracy limit primary current: 300A
Protection : 5 times Protection, 10 times protection 
 5-600A 0.333V Split Core Current Transformer

Model No. 3 :GWSCCT024
Ratio : 3000:1 
Rated input: 100A 150A 200A 250A 
Accuracy class: 0.5 1.0S
Rated accuracy limit primary current: 540A
Protection : 5 times Protection, 10 times protection
 
Model No.4:GWSCCT035
Rated input: 200A 300A 400A 600A
 Accuracy class: 0.5 1.0S
Rated accuracy limit primary current: 600A
Protection : 5 times Protection, 10 times protection
Frequency: 50--400Hz


The GREWIN SCCT series of split core ct style current sensors are designed for fast and easy installation.The split core design permits non-contactcurrent measurements through magnetic field induction without disconnecting cables or busbar circuits for CT installation. This method permits a safer, easier and portable current measurement.
0.333-3.53V rated secondary output split core current transformer :
 
0.333V Split CT Current Transformer for Electrical Motor and HVAC

Model No 1 :GWSCCT681B -010
Ratio : 3000:1
Rated input: 5A 10A 20A 50A 75A
Accuracy class: 1.0s  3.0s
Rated primary current :120A
Protection: 5 times protection ,10 times protection like 25A 50A 100A 200A 250A 385A 500A 750A
 
Model No.2 :GWSCC681B-016
Ratio :3000:1
Rated input: 75A 100A 150A
Accuracy class: 0.5 1.0S
Rated accuracy limit primary current: 300A
Protection : 5 times Protection, 10 times protection 
 
0.333V Split CT Current Transformer for Electrical Motor and HVAC

Model No. 3:GWSCC681B-024
Ratio : 3000:1 
Rated input: 100A 150A 200A 250A 
Accuracy class: 0.5 1.0S
Rated accuracy limit primary current: 540A
Protection : 5 times Protection, 10 times protection
 
Model No.4:GWSCC681B-035
Rated input: 200A 300A 400A 600A
 Accuracy class: 0.5 1.0S
Rated accuracy limit primary current: 600A
Protection : 5 times Protection, 10 times protection
Frequency: 50--400Hz
0.333V Split CT Current Transformer for Electrical Motor and HVAC
0.333V Split CT Current Transformer for Electrical Motor and HVAC

5-600A 50-400Hz Split Core Current Transformer for Current Measurement
5-600A 50-400Hz Split Core Current Transformer for Current Measurement5-600A 50-400Hz Split Core Current Transformer for Current Measurement

CONTACT INFO:

TIANJIN GREWIN TECHNOLOGY CO.,LTD
Add:Meinian Plaza.No.16 Dongting Road,Hexi Distr,Tianjin,China .
 
Web: transformer.en.made-in-china.com
 





 


 

Contact us