0.333mv 1000A AC Hall Effect Current Sensor Meter Clamp Probe Meter

PRODUCT:0.333mv 1000A AC hall effect Current Sensor meter Clamp Probe Meter 1.GWCTP1535 0.1A-1000A:Current probe(specifications)Rated Primary current0.1A-1000AOutput signalmA/A or mV/A Maximum Non-Destructive Current2000ABasic Accuracy1%SafetyCAT III 600VDielectric Resistance1000MOhms @ 500 VdcCase MaterialPolypro

Featured Products

PRODUCT:0.333mv 1000A AC hall effect Current Sensor meter Clamp Probe Meter 

0.333mv 1000A AC Hall Effect Current Sensor Meter Clamp Probe Meter




0.333mv 1000A AC Hall Effect Current Sensor Meter Clamp Probe Meter

1.GWCTP1535 0.1A-1000A:
Current probe(specifications)
Rated Primary current0.1A-1000A
Output signalmA/A or mV/A
 Maximum Non-Destructive Current2000A
Basic Accuracy1%
SafetyCAT III 600V
Dielectric Resistance1000MOhms @ 500 Vdc
Case MaterialPolypropylene resinUL flame retardant rating 94-V0
Voltage rank600Vac(isolated condition), 30Vac(bareness condition)
Maximum voltage600Vac
Useable frequency10Hz - 100kHz
Maximum Cable Diameter2.05 inches (52 mm)
 Dimensions 4.37x8.5 x1.77 in. (111x216x45 mm)
Operating Temperature-10ºC to +50ºC
StandardIEC 60044-1
AccessoriesSupplied with feet for base mounting if required
CertificationRoHS compliant CE&ETL approved
 
Current probe(features)
Good appearance
Low cost
5 standard sizes
Clamp-on core design,safer,easier installation, portable
Both Silicon Steel & Nickel Alloy cores available
Current or three specs voltage output signal
Current probe(applications)
Current, power energy,monitoring devices
Power Factor Correction devices
Oscilloscope and harmonic waves analyzer
 
 
Part numberInput currentRated OutputFrequency
(Hz)
Secondary
Burden
Resistance
Accuracy
Class
GWCTP15350.5-1000A1mA/A40-1KHZ≤10 Ohms1%
400-1000A5A,1A50/60HZ≤2VA1%
0.1-10A100mV/A10-1000K≥100KOhms3%±10mV
0.1-100A10mV/A2%±5mV
1-1000A1mV/A1%±1mV
0.5-1000A4-20mA50/60HZ≤100 Ohms1%
 
0.333mv 1000A AC Hall Effect Current Sensor Meter Clamp Probe Meter
GWQCT03 Clamp sensor Specification :
Technical datas:
Rated primary current:Max 500A  AC
Output voltage:333 mV AC
Amplitude accuracy:±0.5% rdg.±0.1%f.s. (f.s.:500A, 45Hz - 66Hz, Primary conductor in the enter)
Phase accuracy±1°(10~100%I1n)(45 Hz - 5 kHz)
The amplitude frequency characteristic±1% (45 Hz - 5 kHz) ( Deviation  Accuracy)
Conductor impact±0.5%(off-center)
The influence of external electromagnetic fields≤0.1 A(in AC 400A /M electromagnetic fields)
Maximum input current550A  AC continuous (45-66 HZ  Ambient  temperature 50°C)
Temperature coefficient0.02 %reading data /°C
Dielectric strength5312 V ACrms /continuous 15s (circuits- core)
Maximum rated voltage600V ACrms
Woring temperature& humidity0 to 50°C (32 - 122°F), ≤80%RH (No condensate)
Woring temperature& humidity-10 to 60°C (14 - 140°F), ≤80%RH (No condensate)
Indoor  using and up to 2000m above sea  level
Standardssacurity:EN61010 - 2 -032:2002 , CAT III,contamination II
EMC:EN61326:1997+A1:1998+A2:2001+A3:2003(Class A)  
Measure conductor diameter≤Φ46mm
Cable length2m
SizeAbout 78W x 160H x 40D mm(excluding protruding parts)
weightAbout 380g
AccessoryInstrution manul  one piece
  f.s. :Maximum display datas or scale length
 rdg:Reading value (the value of the current is measured and displayed in the measurement of the product)


We can produce following similar clamp on current transformer GWCTC Series : 0.333mv 1000A AC Hall Effect Current Sensor Meter Clamp Probe Meter0.333mv 1000A AC Hall Effect Current Sensor Meter Clamp Probe Meter
Clamp on current transformer(applications)
Silicon Steel cores provide moderate accuracy and lower cost for appropriate current measurement
Nickel Alloy cores are suitable for applications that require the highest accuracy with minimal
 phase angle error.Applications would include electric power quality monitoring devices
Clamp on current transformer(specifications)
Rated Primary current1-200A
Turn ratio1:1000 1:2000 1:2500
Output0.333V 1.5V
Accuracy0.1, 0.2 ,1.0 Class
Second burden(Ohms)<5, <50 ,>100k
Dielectric Resistance1000MOhms @ 500 Vdc
Case MaterialPolypropylene resinUL flame retardant rating 94-V0
Voltage rank600Vac(isolated condition), 30Vac(bareness condition)
High Potential2500Volts/min
Frequency Range:50/60Hz
Operating Temperature-25ºC to +70ºC
StandardIEC 60044-1
AccessoriesSupplied with feet for base mounting if required
CertificationRoHS compliant CE&ETL approved
 Part
Number
Rated
Input
(A)
Turn
Ratio
Frequency
( Hz )
Secondary
Burden
Resistance
(Ohms)
Accuracy
Class
Outline 
Dimensions 
(mm)
 GWCTP0080N 1~501:1000
1:2000
1:2500
...
50 to 400≤500.1
0.2
ID-L-W-H
8.0-46.0-27.0-171
 GWCTP0130N5~20050 to 400≤50.1
0.2
ID-L-W-H
13.0-52.0-27.0-174
 GWCTP0200N5~20050 to 400≤50.1
0.2
ID-L-W-H
20.0-52.0-27.0-180
 GWLCTP0250 Input:100A
 Output:0.333,
1.5V
--50 to 1K≥100k1.0ID-L-W-H
25.0-50.0-19.5-87
Tianjin Grewin Technology Co.,Ltd
Clamp on current transformer(features)
Low cost
5 standard sizes
 Clamp-on core design,safer,easier installation, portable
Both Silicon Steel & Nickel Alloy cores available
Clamp on current transformer(applications)
Silicon Steel cores provide moderate accuracy and lower cost for appropriate current measurement
Nickel Alloy cores are suitable for applications that require the highest accuracy with minimal phase angle error. Applications would include electric power quality monitoring devices
0.333mv 1000A AC Hall Effect Current Sensor Meter Clamp Probe Meter
0.333mv 1000A AC Hall Effect Current Sensor Meter Clamp Probe Meter


Contact Information:                                                     
Alice.Lee
 
Tianjin Grewin Technology Co.,Ltd.
Web: transformer.en.made-in-china.com




 
 

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours