Datasheet | MIN-2500TL-X | MIN-3000TL-X | MIN-3600TL-X | MIN-4200TL-X | MIN-4600TL-X | MIN-5000TL-X | MIN-6000TL-X |
Input Data (DC) | |||||||
Max. recommended PV power (for module STC) | 3500W | 4200W | 5040W | 5880W | 6440W | 7000W | 8100W |
Max. DC voltage | 500V | 500V | 550V | 550V | 550V | 550V | 550V |
Start voltage | |||||||
MPP voltage range | 80V-500V | 80V-500V | 80V-550V | 80V-550V | 80V-550V | 80V-550V | 80V-550V |
No. of MPP trackers | 2 | ||||||
No. of PV strings per MPP tracker | 1 | ||||||
Max. input current per MPP tracker | 12.5A | ||||||
Max. short-circuit current per MPP tracker | 16A | ||||||
Output data (AC) | |||||||
AC nominal power | 2500W | 3000W | 600W | 4200W | 4600W | 5000W | 6000W |
Max. AC apparent power | 2500VA | 3000VA | 3600VA | 4200VA | 4600VA | 5000VA | 6000VA |
Nominal AC voltage(range*) | 230V (180-280V) | ||||||
AC grid frequency(range*) | 50/ 60 Hz (45-55Hz/55-65 Hz) | ||||||
Max. output current | 11.3A | 13.6A | 16A | 19A | 20.9A | 22.7A | 27.2A |
Adjustable power factor | 0.8leading…0.8lagging | ||||||
THDi | <3% | ||||||
AC grid connection type | Single phase | ||||||
Efficiency | |||||||
Max.efficiency | 98.2% | 98.2% | 98.2% | 98.4% | 98.4% | 98.4% | 98.4% |
European efficiency | 97.1% | 97.1% | 97.2% | 97.5% | 97.5% | 97.5% | 97.5% |
MPPT efficiency | 99.9% | ||||||
Protection Devices | |||||||
DC reverse polarity protection | yes | ||||||
DC switch | yes | ||||||
AC/DC surge protection | Type II / Type III | ||||||
Insulation resistance monitoring | yes | ||||||
AC short-circuit protection | yes | ||||||
Ground fault monitoring | yes | ||||||
Grid monitoring | yes | ||||||
Anti-islanding protection | yes | ||||||
Residual-current monitoring unit | yes | ||||||
AFCI protection | Optional | ||||||
General Data | |||||||
Dimensions (W / H / D) | 375/350/160mm | ||||||
Weight | 10.8kg | ||||||
Operating temperature range | -25°C ... +60°C | ||||||
Noise emission (typical) | ≤35 dB(A) | ||||||
Nighttime power consumption | < 1W | ||||||
Topology | Transformerless | ||||||
Cooling | Natural convection | ||||||
Protection degree | IP65 | ||||||
Relative humidity | 0-100% | ||||||
Altitude | 4000m | ||||||
DC connection | H4/MC4(Optional) | ||||||
AC connection | Connector | ||||||
Display | OLED+LED/WIFI+APP | ||||||
Interfaces: RS485 / USB/Wi-Fi/ GPRS/ RF/LAN | Yes/Yes/Optional/Optional/Optional /Optional | ||||||
Warranty: 5 years / 10 years | Yes /Optional | ||||||
CE, IEC62109, VDE0126-1-1, AS4777, AS/NZS 3100, VDE-AR-N4105, CQC, IEC61683, IEC60068, IEC61727, IEC62116, INMETRO |
Package
Global Projects