D7- 1000A Series Closed Loop Current Sensor 1000A Hall Effect Current Sensor

Product Feature: The D7 Series current sensor is a closed loop device based on the measuring principle of the hall effect, with a galvanic isolation between primary and secondary circuit,&nb

Featured Products

Product Feature:

 

The D7 Series current sensor is a closed loop device based on the measuring principle of the hall effect,

 with a galvanic isolation between primary and secondary circuit,

 the size of primary doesn't affect test precision, no matter the location of primary in the hole of current sensor.

 It can really measure resolution 1000:1, it uses for precision measurement of DC, AC and pulse current. 

 

(Ta=25 ±5 ,RL=2KΩ,CL=10000PF)

 

Type

D7-1000A

Unit

Rated current(Ipn)

±1000

A

Measure range(Ip)

0-±2000

A

Turns ratio(Np/Ns)

1:5000

T

Measure resister 

with±15V

@±1000Amax,        0(min)30(max)

Ω

@±2000Amax,        0(min)20(max)

Ω

Measure resister 

with±24V

@±1000Amax,        0(min)75(max)

Ω

@±2000Amax,        0(min)15(max)

Ω

Coil resister

37

Ω

Rated output

200

mA

Supply voltage

±15,±18,±24

V

Power Consumption

≤20+IpX(Np/Ns)

mA

Offset current

@Ip=0                     ±0.2

mA

Offset drift

@ -40~+85              ≤±0.25

mA

Linearity 

@Ip=0-±Ipn                 ≤0.1

%FS

Response time

@50A/μS, 10%-90%         ≤1

μS

Galvanic isolation

@ 50HZ,AC,1min              6

KV

di/dt

>100

A/us

Bandwidth

@ -1dB                    0~100

KHZ

 

Applications

 

·Variable speed drives

·Welding machine

·Battery supplied applications

·Uninterruptible Power Supplies (UPS)

·Electrochemical

 

 Mechanical dimension (for reference only) 

D7-1000A Series Closed Loop Current Transducer 1000A Hall Effect Current Transducer
 

 

 

Remarks:

1. All dimensions are in mm.

2. General tolerance ±1mm

3. Elucidation:  1:+15V  2:-15V  3:I0UT  4:NC

 

Directions for use

 

1.When the current will be measured goes through a sensor, the current will be measured at the output end.  (Note: The false wiring may result in the damage of the sensor)

2.Custom design in the different rated input current and the output current are available.

 

Standards

 

·UL94-V0.

·EN60947-1:2004

·IEC60950-1:2001

·EN50178:1998

·SJ 20790-2000

 

General date

 

 

Value

Unit

Operating temperature (TA)

-40 to +85

 

Storage temperature (TS)

-40 to +125

 

Mass(approx) (M)

       460

g

Characteristics chart

 

 

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours