Current Clamp for AC Current AC Clamp Ce UL Clamp Leakage Current Sensor on 1000A/5A Current Transformer

General Information:EP6410S clamp-type leakage current sensor, also known as clamp-type current transformer, is suitable for AC current, leakage current, higher harmonic current, phase, energy, power, power factor and other detection. Portable clamp design, no need to disconnect the tested line, non-contact measurement, safe and

Featured Products

General Information:
EP6410S clamp-type leakage current sensor, also known as clamp-type current transformer, is suitable for AC current, leakage current, higher harmonic current, phase, energy, power, power factor and other detection. Portable clamp design, no need to disconnect the tested line, non-contact measurement, safe and fast, can be connected to multimeter, energy meter, phase detection analyzer, industrial control device, data recorder, oscilloscope, harmonic analyzer, power quality analysis Instrument, high-precision digital multimeter, etc. Widely used in electric power, communication, meteorology, railway, oil field, construction, measurement, scientific research and teaching units, industrial and mining enterprises and other fields.
EP6410S clamp-type leakage current sensor uses special alloy for the iron core of the clamp head and adopts the latest magnetic shielding technology. The influence of the external magnetic field is minimal. Its core cross-sectional size reaches 15mmx8mm. High precision, high stability and high reliability of measurement.


Technical Specifications:
FunctionDetection of AC current, leakage current, higher harmonic current, phase, energy, power, power factor, etc.
Detection methodClamp CT
Clamp sizeφ52mm
Range 0 ~ 1000A AC
Resolution 0.01mA AC
Ratio1000A / 1A
Output 1mA / 1A
Accuracy 0.5 class  (50Hz / 60Hz, 23 ºC ± 2 ºC, below 70% RH, the wire is in the center of the jaw)
Phase shift1 ° (50Hz / 60Hz,  23 ºC ± 2 ºC)
Core section size 15mmx8mm
Reference load RL:0 ~ 100mA3kΩ
0 ~ 10A30Ω
0 ~ 1000A0.3Ω
Input indicatorThe arrow indicates the current input direction
Output methodCurrent sensing output
Output interfaceRed and black banana plug, standard 4mm multimeter pen plug
Output wire lengthφ5mm, length 1.6m
Wire positionThe wire under test is in the center of the jaw
Current frequency45Hz ~ 60Hz (the measured current frequency)
Core frequency 10Hz ~100kHz
Line voltageAC 600V below line test
Dimensionslength, width and thickness: about 220mm × 106mm × 46mm
Weight665g
Working temperature and humidity-20 ºC ~ 50 ºC, below 80% rh
Storage temperature and humidity-10 ºC ~ 60 ºC, below 70% rh
Insulation strengthAC 2000V / rms (between iron core and the shell)
Suitable for safety regulationsIEC1010-1, IEC1010-2-032, pollution 2. CAT III (600V)

Please contact EP Hipot for more details.

Current Clamp for AC Current 1000A/5A AC Clamp on Current Transformer Ce UL Clamp Type Leakage Current Sensor
Current Clamp for AC Current 1000A/5A AC Clamp on Current Transformer Ce UL Clamp Type Leakage Current Sensor
Current Clamp for AC Current 1000A/5A AC Clamp on Current Transformer Ce UL Clamp Type Leakage Current Sensor

 

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours